{"product_id":"apc-easy-ups-3s-parallel-maintenance-bypass-panel-10-40kva","title":"APC Easy UPS 3S Parallel Maintenance Bypass Panel 10-40kVA","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"who-its-for\"\u003e\u003ch1\u003eAPC Easy UPS 3S Parallel Maintenance Bypass Panel for 3 UPSs\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEasy UPS 3S Parallel Maintenance Bypass Panel\u003c\/strong\u003e is engineered for organizations requiring seamless maintenance operations on parallel UPS configurations. This \u003cstrong\u003emaintenance bypass solution\u003c\/strong\u003e supports 3 UPSs in parallel topology, delivering 10-40kVA capacity at 208V, making it ideal for data centers, enterprise IT environments, and critical infrastructure requiring zero-downtime maintenance. The bypass panel enables safe equipment servicing without interrupting power delivery to connected loads, ensuring business continuity while performing essential maintenance tasks on your parallel UPS system.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 3 UPSs in parallel configuration for redundant power delivery\u003c\/li\u003e\n\u003cli\u003e10-40kVA capacity range accommodates mid-to-large enterprise deployments\u003c\/li\u003e\n\u003cli\u003e208V single-phase input\/output for North American installations\u003c\/li\u003e\n\u003cli\u003eMaintenance bypass functionality enables safe UPS servicing without load interruption\u003c\/li\u003e\n\u003cli\u003eIntegrated with Easy UPS 3S ecosystem for simplified management\u003c\/li\u003e\n\u003cli\u003eSchneider Electric reliability and industry-leading support\u003c\/li\u003e\n\u003cli\u003eCompact design optimizes data center floor space utilization\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"technical-specs\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"8\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eEasy UPS 3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eE3SBPAR10K40F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Configuration\u003c\/td\u003e\n\u003ctd\u003e3 UPSs Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003e10-40kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output Voltage\u003c\/td\u003e\n\u003ctd\u003e208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eMaintenance Bypass Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eData Centers, Enterprise IT, Critical Infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is a maintenance bypass panel for parallel UPS systems?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003emaintenance bypass panel\u003c\/strong\u003e allows you to safely service or replace UPS units in a parallel configuration without interrupting power to your critical loads. It automatically transfers the load to the bypass source during maintenance windows, ensuring zero downtime.\u003c\/p\u003e\n\u003ch3\u003eHow many UPSs can this parallel maintenance bypass panel support?\u003c\/h3\u003e\n\u003cp\u003eThe E3SBPAR10K40F is specifically designed to support \u003cstrong\u003e3 UPSs in parallel\u003c\/strong\u003e, providing redundancy and load-sharing capabilities for enterprise-grade power protection.\u003c\/p\u003e\n\u003ch3\u003eIs this bypass panel compatible with other UPS models?\u003c\/h3\u003e\n\u003cp\u003eThis panel is engineered for the \u003cstrong\u003eEasy UPS 3S\u003c\/strong\u003e product line. Compatibility should be verified with your specific UPS models and Schneider Electric technical documentation before installation.\u003c\/p\u003e\n\u003ch3\u003eWhat voltage configuration does this maintenance bypass panel support?\u003c\/h3\u003e\n\u003cp\u003eThe E3SBPAR10K40F operates at \u003cstrong\u003e208V\u003c\/strong\u003e, making it suitable for standard North American three-phase power environments commonly found in data centers and enterprise facilities.\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"APC BY SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":41675707973707,"sku":"E3SBPAR10K40F","price":9933.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/APC-Easy-UPS-3S-Parallel-Maintenance-Bypass-Panel-10-40kVA.jpg?v=1788299888","url":"https:\/\/www.tecisoft.com\/products\/apc-easy-ups-3s-parallel-maintenance-bypass-panel-10-40kva","provider":"TeciSoft","version":"1.0","type":"link"}