{"product_id":"apc-galaxy-vs-parallel-maintenance-bypass-panel-40-50kw","title":"APC Galaxy VS Parallel Maintenance Bypass Panel 40-50kW","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"who-its-for\"\u003e\u003ch1\u003eAPC Galaxy VS Parallel Maintenance Bypass Panel – 40-50kW, 400V\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eAPC parallel maintenance bypass panel\u003c\/strong\u003e is engineered for organizations running dual UPS systems that require safe, uninterrupted power isolation during maintenance operations. Designed specifically for \u003cstrong\u003eGalaxy VS and Easy UPS 3S\u003c\/strong\u003e configurations, this 40-50kW, 400V wall-mounted solution enables IT teams to perform critical UPS maintenance without shutting down protected equipment. Whether you're managing enterprise data centers, mission-critical facilities, or high-availability infrastructure, this \u003cstrong\u003eparallel bypass panel\u003c\/strong\u003e ensures operational continuity while protecting your dual UPS investment.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eParallel maintenance bypass for 2 UPS units – seamless power transfer during service\u003c\/li\u003e\n\u003cli\u003e40-50kW capacity with 400V three-phase input – supports enterprise-scale deployments\u003c\/li\u003e\n\u003cli\u003eWall-mounted design – space-efficient installation for Galaxy VS and Easy UPS 3S\u003c\/li\u003e\n\u003cli\u003eDual UPS isolation capability – maintain power to critical loads during individual UPS maintenance\u003c\/li\u003e\n\u003cli\u003eAPC Schneider Electric engineering – proven reliability and compatibility\u003c\/li\u003e\n\u003cli\u003eAutomatic bypass switching – minimizes downtime during maintenance windows\u003c\/li\u003e\n\u003cli\u003eIntegrated monitoring compatibility – works with APC management systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"specifications\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"10\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eGVSBPAR40K50H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eParallel Maintenance Bypass Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible UPS Models\u003c\/td\u003e\n\u003ctd\u003eGalaxy VS, Easy UPS 3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003e40-50 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e400V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of UPS Units\u003c\/td\u003e\n\u003ctd\u003e2 (Dual UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eUPS isolation and maintenance bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is a parallel maintenance bypass panel used for?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eparallel maintenance bypass panel\u003c\/strong\u003e allows you to isolate one UPS unit from your dual UPS system while maintaining continuous power to your critical equipment through the other unit. This enables safe maintenance, testing, or replacement without downtime.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eCan this bypass panel work with Galaxy VS and Easy UPS 3S together?\u003c\/h3\u003e\n\u003cp\u003eYes, this APC parallel bypass panel is specifically designed for both Galaxy VS and Easy UPS 3S series UPS systems, making it ideal for mixed deployments or standardized enterprise environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eIs wall mounting suitable for 40-50kW UPS systems?\u003c\/h3\u003e\n\u003cp\u003eAbsolutely. The wall-mounted design is engineered for the GVSBPAR40K50H to integrate seamlessly with Galaxy VS and Easy UPS 3S installations, optimizing floor space in data centers and server rooms while maintaining full functionality.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow does this parallel bypass panel improve UPS maintenance?\u003c\/h3\u003e\n\u003cp\u003eBy enabling safe isolation of individual UPS units in a dual configuration, this maintenance bypass panel eliminates the need for complete system shutdowns during service, reducing operational risk and extending equipment lifespan through planned maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"APC BY SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":41695639830603,"sku":"GVSBPAR40K50H","price":5233.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/APC-Galaxy-VS-Parallel-Maintenance-Bypass-Panel-40-50kW.jpg?v=1788303913","url":"https:\/\/www.tecisoft.com\/products\/apc-galaxy-vs-parallel-maintenance-bypass-panel-40-50kw","provider":"TeciSoft","version":"1.0","type":"link"}