{"product_id":"eaton-eaton-9px-g2-11000va-11000w-208-120v-online-double-conversion-ups","title":"EATON Eaton 9PX G2 11000VA 11000W 208\/120V Online Double-Conversion UPS","description":"\u003cp data-start=\"52\" data-end=\"396\"\u003eThe \u003cstrong data-start=\"56\" data-end=\"77\"\u003eEaton 9PX11KTF5G2\u003c\/strong\u003e is a \u003cstrong data-start=\"83\" data-end=\"130\"\u003ehigh-capacity, online double-conversion UPS\u003c\/strong\u003e built to deliver clean, continuous power for \u003cstrong data-start=\"176\" data-end=\"220\"\u003emission-critical IT and electrical loads\u003c\/strong\u003e. With a \u003cstrong data-start=\"229\" data-end=\"252\"\u003epower factor of 1.0\u003c\/strong\u003e, it provides \u003cstrong data-start=\"266\" data-end=\"282\"\u003e11kVA \/ 11kW\u003c\/strong\u003e of usable output to protect sensitive equipment from outages, voltage fluctuations, surges, and electrical noise.\u003c\/p\u003e\n\u003cp data-start=\"398\" data-end=\"713\"\u003eThis model is a \u003cstrong data-start=\"414\" data-end=\"438\"\u003erack\/tower 7U bundle\u003c\/strong\u003e designed for environments that need \u003cstrong data-start=\"475\" data-end=\"489\"\u003e208V input\u003c\/strong\u003e and \u003cstrong data-start=\"494\" data-end=\"513\"\u003e120\/208V output\u003c\/strong\u003e distribution. It includes a \u003cstrong data-start=\"542\" data-end=\"567\"\u003estep-down transformer\u003c\/strong\u003e and a \u003cstrong data-start=\"574\" data-end=\"603\"\u003emaintenance bypass module\u003c\/strong\u003e, and it also comes with a \u003cstrong data-start=\"630\" data-end=\"665\"\u003eNETWORK-M3 Gigabit network card\u003c\/strong\u003e for remote monitoring and shutdown integration.\u003c\/p\u003e\n\u003ch4 data-start=\"715\" data-end=\"732\"\u003eWho it’s for\u003c\/h4\u003e\n\u003cul data-start=\"733\" data-end=\"1140\"\u003e\n\u003cli data-start=\"733\" data-end=\"838\"\u003e\n\u003cp data-start=\"735\" data-end=\"838\"\u003e\u003cstrong data-start=\"735\" data-end=\"771\"\u003eServer rooms and network closets\u003c\/strong\u003e powering servers, switches, storage, and VoIP\/PoE infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"839\" data-end=\"947\"\u003e\n\u003cp data-start=\"841\" data-end=\"947\"\u003e\u003cstrong data-start=\"841\" data-end=\"861\"\u003eEdge deployments\u003c\/strong\u003e and small-to-mid-size data center environments needing true online power protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"948\" data-end=\"1061\"\u003e\n\u003cp data-start=\"950\" data-end=\"1061\"\u003e\u003cstrong data-start=\"950\" data-end=\"1015\"\u003eHealthcare, government, industrial IT, and enterprise offices\u003c\/strong\u003e where uptime and power quality are critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1062\" data-end=\"1140\"\u003e\n\u003cp data-start=\"1064\" data-end=\"1140\"\u003eTeams that want \u003cstrong data-start=\"1080\" data-end=\"1117\"\u003eremote UPS visibility and control\u003c\/strong\u003e via network monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1142\" data-end=\"1145\"\u003e\n\u003ch2 data-start=\"1147\" data-end=\"1166\"\u003eBrief Spec Table\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1168\" data-end=\"1770\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1168\" data-end=\"1186\"\u003e\n\u003ctr data-start=\"1168\" data-end=\"1186\"\u003e\n\u003cth data-start=\"1168\" data-end=\"1175\" data-col-size=\"sm\"\u003eSpec\u003c\/th\u003e\n\u003cth data-start=\"1175\" data-end=\"1186\" data-col-size=\"md\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1197\" data-end=\"1770\"\u003e\n\u003ctr data-start=\"1197\" data-end=\"1242\"\u003e\n\u003ctd data-start=\"1197\" data-end=\"1212\" data-col-size=\"sm\"\u003eUPS topology\u003c\/td\u003e\n\u003ctd data-start=\"1212\" data-end=\"1242\" data-col-size=\"md\"\u003eOnline \/ Double-conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1243\" data-end=\"1281\"\u003e\n\u003ctd data-start=\"1243\" data-end=\"1254\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-start=\"1254\" data-end=\"1281\" data-col-size=\"md\"\u003e11 kVA \/ 11 kW (PF 1.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1282\" data-end=\"1319\"\u003e\n\u003ctd data-start=\"1282\" data-end=\"1291\" data-col-size=\"sm\"\u003eOutput\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1291\" data-end=\"1319\"\u003e120\/208V, true sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1320\" data-end=\"1389\"\u003e\n\u003ctd data-start=\"1320\" data-end=\"1328\" data-col-size=\"sm\"\u003eInput\u003c\/td\u003e\n\u003ctd data-start=\"1328\" data-end=\"1389\" data-col-size=\"md\"\u003eHardwired; 208V (supports common 200–240V nominal ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1390\" data-end=\"1422\"\u003e\n\u003ctd data-start=\"1390\" data-end=\"1404\" data-col-size=\"sm\"\u003eForm factor\u003c\/td\u003e\n\u003ctd data-start=\"1404\" data-end=\"1422\" data-col-size=\"md\"\u003eRack\/Tower, 7U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1423\" data-end=\"1477\"\u003e\n\u003ctd data-start=\"1423\" data-end=\"1433\" data-col-size=\"sm\"\u003eNetwork\u003c\/td\u003e\n\u003ctd data-start=\"1433\" data-end=\"1477\" data-col-size=\"md\"\u003eIncludes NETWORK-M3 Gigabit network card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1478\" data-end=\"1547\"\u003e\n\u003ctd data-start=\"1478\" data-end=\"1493\" data-col-size=\"sm\"\u003eBattery type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1493\" data-end=\"1547\"\u003eSealed lead-acid; hot-swappable internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1548\" data-end=\"1612\"\u003e\n\u003ctd data-start=\"1548\" data-end=\"1568\" data-col-size=\"sm\"\u003eRuntime expansion\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1568\" data-end=\"1612\"\u003eSupports external battery modules (EBMs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1613\" data-end=\"1680\"\u003e\n\u003ctd data-start=\"1613\" data-end=\"1626\" data-col-size=\"sm\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd data-start=\"1626\" data-end=\"1680\" data-col-size=\"md\"\u003eHigh-efficiency operation (up to ~97% at max load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1681\" data-end=\"1770\"\u003e\n\u003ctd data-start=\"1681\" data-end=\"1703\" data-col-size=\"sm\"\u003eIncluded components\u003c\/td\u003e\n\u003ctd data-start=\"1703\" data-end=\"1770\" data-col-size=\"md\"\u003eUPS + step-down transformer + maintenance bypass + network card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1772\" data-end=\"1775\"\u003e\n\u003ch2 data-start=\"1777\" data-end=\"1787\"\u003eFAQ (5)\u003c\/h2\u003e\n\u003cp data-start=\"1789\" data-end=\"1975\"\u003e\u003cstrong data-start=\"1789\" data-end=\"1842\"\u003e1) Is this a true online (double-conversion) UPS?\u003c\/strong\u003e\u003cbr data-start=\"1842\" data-end=\"1845\"\u003eYes. It uses online\/double-conversion topology to continuously condition power and isolate your equipment from power disturbances.\u003c\/p\u003e\n\u003cp data-start=\"1977\" data-end=\"2159\"\u003e\u003cstrong data-start=\"1977\" data-end=\"2034\"\u003e2) Does it include network monitoring out of the box?\u003c\/strong\u003e\u003cbr data-start=\"2034\" data-end=\"2037\"\u003eYes. It includes the \u003cstrong data-start=\"2058\" data-end=\"2080\"\u003eNETWORK-M3 Gigabit\u003c\/strong\u003e network card for remote monitoring, alerts, and graceful shutdown integration.\u003c\/p\u003e\n\u003cp data-start=\"2161\" data-end=\"2353\"\u003e\u003cstrong data-start=\"2161\" data-end=\"2201\"\u003e3) Is a maintenance bypass included?\u003c\/strong\u003e\u003cbr data-start=\"2201\" data-end=\"2204\"\u003eYes. This bundle includes a maintenance bypass module so you can service the UPS without dropping power to connected loads (when properly installed).\u003c\/p\u003e\n\u003cp data-start=\"2355\" data-end=\"2506\"\u003e\u003cstrong data-start=\"2355\" data-end=\"2402\"\u003e4) Can I extend runtime for longer outages?\u003c\/strong\u003e\u003cbr data-start=\"2402\" data-end=\"2405\"\u003eYes. You can add external battery modules (EBMs) to increase runtime based on your load requirements.\u003c\/p\u003e\n\u003cp data-start=\"2508\" data-end=\"2702\"\u003e\u003cstrong data-start=\"2508\" data-end=\"2555\"\u003e5) What environments is it best suited for?\u003c\/strong\u003e\u003cbr data-start=\"2555\" data-end=\"2558\"\u003eIt’s ideal for \u003cstrong data-start=\"2573\" data-end=\"2638\"\u003eserver rooms, closets, edge IT, and critical business systems\u003c\/strong\u003e that require reliable, conditioned power and remote management.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":42029006356555,"sku":"9PX11KTF5G2","price":10836.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/EATON-Eaton-9PX-G2-11000VA-11000W-208120V-Online-Double-Conversion-UPS.jpg?v=1768230957","url":"https:\/\/www.tecisoft.com\/products\/eaton-eaton-9px-g2-11000va-11000w-208-120v-online-double-conversion-ups","provider":"TeciSoft","version":"1.0","type":"link"}