{"product_id":"panduit-os2-sm-24-fiber-plenum-front-access-cassette-lc-apc","title":"Panduit OS2 SM 24-Fiber Plenum Front Access Cassette","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"who-its-for\"\u003e\u003ch1\u003ePanduit OS2 SM 24-Fiber Plenum Front Access Cassette with LC\/APC Connectors\u003c\/h1\u003e\n\u003cp\u003eThis \u003cstrong\u003eOS2 single-mode 24-fiber plenum cassette\u003c\/strong\u003e is engineered for data centers, telecommunications facilities, and enterprise networks requiring high-density fiber connectivity with front-access convenience. The \u003cstrong\u003e24-fiber front access cassette\u003c\/strong\u003e delivers reliable performance in plenum-rated environments, making it ideal for building infrastructure where fire safety compliance is critical. With tethered LC\/APC connectors and a 30-foot tether, this solution simplifies deployment while maintaining standard insertion loss specifications for consistent network performance.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24-Fiber Capacity\u003c\/strong\u003e — Maximize density in compact rack spaces with single-mode fiber support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Access Design\u003c\/strong\u003e — Simplify maintenance and reconfiguration without rear panel access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlenum-Rated Construction\u003c\/strong\u003e — Meets fire safety standards for installation in air-handling spaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTethered LC\/APC Connectors\u003c\/strong\u003e — 30-foot tether prevents connector loss and streamlines field deployment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeft Orientation\u003c\/strong\u003e — Optimized cable routing for specific rack configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Insertion Loss\u003c\/strong\u003e — Consistent performance across all 24 fiber channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Mode OS2 Fiber\u003c\/strong\u003e — Long-distance transmission capability for enterprise networks\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"specifications\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ePANDUIT CORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eF9UYPZLNNSNF030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eOS2 Single-Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e24 Fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eLC\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Type\u003c\/td\u003e\n\u003ctd\u003eFront Access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrientation\u003c\/td\u003e\n\u003ctd\u003eLeft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTether Length\u003c\/td\u003e\n\u003ctd\u003e30 Feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsertion Loss\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlenum Rating\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is a 24-fiber plenum cassette used for?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003e24-fiber plenum cassette\u003c\/strong\u003e is used in data centers and telecommunications installations to organize and manage high-density fiber connections in fire-rated plenum spaces. The front access design allows technicians to add, remove, or reconfigure connections without disturbing rear infrastructure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhy choose LC\/APC connectors for fiber networks?\u003c\/h3\u003e\n\u003cp\u003eLC\/APC connectors provide superior return loss performance and are widely adopted in single-mode networks. The angled physical contact (APC) design minimizes back-reflection, making them ideal for long-distance OS2 deployments where signal integrity is critical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat does plenum-rated mean for fiber cassettes?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum-rated\u003c\/strong\u003e means the cassette meets fire safety codes (NFPA 90A) for installation in air-handling spaces above drop ceilings. This certification ensures the product won't release toxic fumes if exposed to fire, making it compliant with building codes in commercial and institutional environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow does the 30-foot tether improve deployment?\u003c\/h3\u003e\n\u003cp\u003eThe tethered LC\/APC connectors prevent accidental disconnection and loss during installation. The 30-foot length provides flexibility for routing cables through cable trays and conduit while keeping connectors securely attached to the cassette.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"PANDUIT CORP","offers":[{"title":"Default Title","offer_id":41685764014155,"sku":"F9UYPZLNNSNF030","price":994.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/Panduit-OS2-SM-24-Fiber-Plenum-Front-Access-Cassette.jpg?v=1788300689","url":"https:\/\/www.tecisoft.com\/products\/panduit-os2-sm-24-fiber-plenum-front-access-cassette-lc-apc","provider":"TeciSoft","version":"1.0","type":"link"}