{"product_id":"panduit-smartzone-g5-intelligent-48-outlets-pdu-p48e13m-bu2c","title":"Panduit P48E13M-BU2C - 48-Outlet Vertical Monitored SmartZone G5 PDU | Tecisoft","description":"\u003cp\u003e This \u003cstrong\u003ePanduit SmartZone G5 vertical monitored PDU\u003c\/strong\u003e is perfect for data centers, server rooms, and enterprise IT facilities who need advanced \u003cstrong\u003eswitched power distribution unit\u003c\/strong\u003e capabilities with comprehensive outlet-level control. Our solution delivers:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e48 outlets\u003c\/strong\u003e with individual switching and monitoring for maximum power management flexibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitored power distribution unit\u003c\/strong\u003e technology providing real-time power consumption data and environmental monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical design\u003c\/strong\u003e optimizing rack space utilization for high-density server environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmartZone G5\u003c\/strong\u003e platform offering advanced power analytics and remote management capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e48 total outlets\u003c\/strong\u003e configuration with (36) C13 and (12) C19 receptacles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched power distribution unit\u003c\/strong\u003e functionality with outlet-level on\/off control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitored power management\u003c\/strong\u003e with real-time current, voltage, and power factor measurements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical rack mount\u003c\/strong\u003e design maximizing available rack space\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmartZone G5\u003c\/strong\u003e intelligence platform with web-based management interface\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring with temperature and humidity sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent power distribution unit\u003c\/strong\u003e features including power consumption trending\u003c\/li\u003e\n\u003cli\u003eSNMP v3 and secure HTTP\/HTTPS protocols for network integration\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable style=\"width:100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP48E13M-BU2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Monitored Switch PDU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSmartZone G5\u003c\/strong\u003e Intelligence System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e48 outlets\u003c\/strong\u003e - (36) C13, (12) C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVertical\u003c\/strong\u003e rack mount design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSwitched\u003c\/strong\u003e with individual outlet control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMonitored\u003c\/strong\u003e - current, voltage, power factor per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature and humidity sensors included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Ethernet with SNMP v3, HTTP\/HTTPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb-based interface, smartphone app support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U \u003cstrong\u003evertical\u003c\/strong\u003e mount in standard 19-inch racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eQ: How does the SmartZone G5 monitoring system help with data center power management?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eSmartZone G5\u003c\/strong\u003e platform provides real-time power monitoring at the outlet level, allowing you to track consumption patterns, set power budgets, and receive alerts for abnormal conditions. This \u003cstrong\u003emonitored power distribution unit\u003c\/strong\u003e capability helps optimize energy efficiency, prevent overloads, and support capacity planning in high-density server environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: What are the advantages of the vertical design for rack installations?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003evertical\u003c\/strong\u003e configuration maximizes rack space efficiency by mounting between server equipment without consuming valuable horizontal rack units. This design is ideal for high-density deployments where every rack unit counts, while still providing \u003cstrong\u003e48 outlets\u003c\/strong\u003e for comprehensive power distribution across multiple servers and networking equipment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: Can I remotely control individual outlets and monitor power consumption?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this \u003cstrong\u003eswitched power distribution unit\u003c\/strong\u003e provides full remote control capabilities through the web interface, SNMP, or smartphone app. You can switch individual outlets on\/off, monitor real-time power consumption, set power thresholds, and receive alerts. The \u003cstrong\u003eintelligent power distribution unit\u003c\/strong\u003e features include power consumption trending and historical data analysis for capacity planning.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: How does this PDU integrate with existing data center monitoring systems?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003emanaged power distribution unit\u003c\/strong\u003e supports industry-standard protocols including SNMP v3, enabling seamless integration with data center infrastructure management (DCIM) platforms, network monitoring systems, and building management systems. The secure HTTPS interface ensures encrypted communication for enterprise security requirements.\u003c\/p\u003e\u003cp class=\"meta-description\"\u003ePanduit SmartZone G5 vertical monitored PDU with 48 outlets. Switched power distribution unit with intelligent monitoring for data centers.\u003c\/p\u003e","brand":"Panduit","offers":[{"title":"Default Title","offer_id":40055411048523,"sku":"P48E13M-BU2C","price":3891.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/Panduit-P48E13M-BU2C-48-Outlet-Vertical-Monitored-SmartZone-G5-PDU-Tecisoft.jpg?v=1768022188","url":"https:\/\/www.tecisoft.com\/products\/panduit-smartzone-g5-intelligent-48-outlets-pdu-p48e13m-bu2c","provider":"TeciSoft","version":"1.0","type":"link"}