{"product_id":"raritan-px3-5961i2u-400v-ipdu-54-outlets","title":"Raritan PX3-5961i2U 400V Intelligent PDU 54 Outlets","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"product-intro\"\u003e\u003ch1\u003eRaritan PX3-5961i2U 400V Intelligent PDU with 54 Outlets\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eRaritan PX3-5961i2U-C8V2A5K2\u003c\/strong\u003e is a high-capacity \u003cstrong\u003e400V intelligent rack PDU\u003c\/strong\u003e engineered for demanding data center environments. With 54 blue outlets and advanced power monitoring capabilities, this \u003cstrong\u003eintelligent power distribution unit\u003c\/strong\u003e delivers precise control over critical IT infrastructure power delivery. Designed for high-density rack deployments, the PX3-5961i2U provides real-time power visibility and management to optimize uptime and reduce operational costs.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e54 blue power outlets for maximum rack density\u003c\/li\u003e\n\u003cli\u003e400V three-phase input for enterprise-grade power delivery\u003c\/li\u003e\n\u003cli\u003eAdvanced power monitoring and metering capabilities\u003c\/li\u003e\n\u003cli\u003eIntelligent outlet-level control and management\u003c\/li\u003e\n\u003cli\u003eReal-time power consumption tracking per outlet\u003c\/li\u003e\n\u003cli\u003eRemote management via network connectivity\u003c\/li\u003e\n\u003cli\u003eSurge protection and overcurrent safeguards\u003c\/li\u003e\n\u003cli\u003eHot-swap capability for continuous operation\u003c\/li\u003e\n\u003cli\u003eCompact 2U form factor for space-efficient installation\u003c\/li\u003e\n\u003cli\u003ePart of Raritan's trusted PX3 series platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"technical-specs\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"8\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRaritan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePX3-5961i2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePX3-5961i2U-C8V2A5K2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e400V three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outlets\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Type\u003c\/td\u003e\n\u003ctd\u003eBlue IEC C13\/C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e2U rack-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Monitoring\u003c\/td\u003e\n\u003ctd\u003eOutlet-level metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interface\u003c\/td\u003e\n\u003ctd\u003eNetwork-based intelligent control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePX3 Intelligent PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is an intelligent PDU and why do I need one?\u003c\/h3\u003e\n\u003cp\u003eAn \u003cstrong\u003eintelligent PDU (iPDU)\u003c\/strong\u003e provides outlet-level power monitoring, remote management, and real-time consumption tracking. Unlike basic PDUs, intelligent units help prevent overloads, optimize power distribution, and reduce downtime in data centers through granular control and visibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow many outlets does the Raritan PX3-5961i2U provide?\u003c\/h3\u003e\n\u003cp\u003eThe PX3-5961i2U features \u003cstrong\u003e54 outlets\u003c\/strong\u003e, making it ideal for high-density rack environments where maximum power outlet availability is critical for connecting multiple servers, switches, and infrastructure equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eIs the PX3-5961i2U suitable for 400V three-phase power systems?\u003c\/h3\u003e\n\u003cp\u003eYes, the \u003cstrong\u003eRaritan PX3-5961i2U is specifically designed for 400V three-phase input\u003c\/strong\u003e, making it perfect for enterprise data centers and facilities with three-phase power infrastructure requiring reliable, monitored power distribution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eCan I manage the PX3-5961i2U remotely?\u003c\/h3\u003e\n\u003cp\u003eThe PX3-5961i2U includes \u003cstrong\u003enetwork-based intelligent management\u003c\/strong\u003e capabilities, allowing remote monitoring and control of individual outlets, power consumption metrics, and alert notifications from anywhere on your network.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"RARITAN","offers":[{"title":"Default Title","offer_id":41731852238923,"sku":"PX3-5961I2U-C8V2A5K2","price":4055.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/Raritan-PX3-5961i2U-400V-Intelligent-PDU-54-Outlets.png?v=1788312408","url":"https:\/\/www.tecisoft.com\/products\/raritan-px3-5961i2u-400v-ipdu-54-outlets","provider":"TeciSoft","version":"1.0","type":"link"}