{"product_id":"transition-networks-j-rs232-cf-01sc-serial-converter-repeater-isolator-rs-232-fiber-sc","title":"RS232 Fiber Media Converter DB-9 Female to 1300nm Multimode SC Serial Converter | Tecisoft J\/RS232-CF-01(SC)-NA","description":"\u003cp\u003e This \u003cstrong\u003eRS232 fiber media converter\u003c\/strong\u003e is perfect for industrial automation engineers, system integrators, and telecommunications professionals who need reliable \u003cstrong\u003eserial to fiber converter\u003c\/strong\u003e solutions for extending RS232 communications over long distances. Our \u003cstrong\u003eJust Convert-IT\u003c\/strong\u003e device delivers:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDB-9 female connector\u003c\/strong\u003e compatibility with standard RS232 serial devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1300nm multimode SC\u003c\/strong\u003e fiber optic interface for extended range communications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFiber optic converter\u003c\/strong\u003e technology eliminating electromagnetic interference\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-grade reliability\u003c\/strong\u003e for mission-critical serial communication applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCopper to fiber conversion\u003c\/strong\u003e extending RS232 communication distances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStand-alone operation\u003c\/strong\u003e requiring no external software or drivers\u003c\/li\u003e\n  \u003cli\u003eOptimized for \u003cstrong\u003eindustrial fiber converter\u003c\/strong\u003e applications in harsh environments\u003c\/li\u003e\n  \u003cli\u003eConsistent \u003cstrong\u003eserial data transmission\u003c\/strong\u003e with transparent protocol handling\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug-and-play installation\u003c\/strong\u003e for immediate deployment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED status indicators\u003c\/strong\u003e for quick diagnostic troubleshooting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact desktop form factor\u003c\/strong\u003e for space-efficient installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"5\"\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransition Networks\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ\/RS232-CF-01(SC)-NA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRS232 Copper to Fiber Stand Alone Media Converter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDB-9 Female connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1300nm Multimode SC connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 bps to 115.2 Kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2 km over multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5\/125µm or 50\/125µm multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal power adapter included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact desktop unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232, EIA\/TIA-232\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eIndustrial automation\u003c\/strong\u003e, SCADA systems, building management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of an RS232 fiber media converter?\u003c\/strong\u003e\u003cbr\u003e\nA: An \u003cstrong\u003eRS232 fiber media converter\u003c\/strong\u003e extends serial communication distances beyond the standard 50-foot copper limitation. This \u003cstrong\u003eserial to fiber converter\u003c\/strong\u003e enables RS232 communication over several kilometers using fiber optic cables, while providing immunity to electromagnetic interference.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How does the DB-9 female connector interface work?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003eDB-9 female connector\u003c\/strong\u003e provides standard RS232 pin configuration compatible with most serial devices. Simply connect your serial cable from your equipment to this converter, and it transparently converts the electrical signals to optical signals for fiber transmission.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What are the advantages of 1300nm multimode fiber transmission?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003e1300nm multimode SC\u003c\/strong\u003e interface operates at an optimal wavelength for multimode fiber, providing up to 2km transmission distance. This \u003cstrong\u003efiber optic converter\u003c\/strong\u003e wavelength minimizes signal attenuation and provides reliable data transmission in industrial environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this converter compatible with existing serial equipment?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, this \u003cstrong\u003eJust Convert-IT\u003c\/strong\u003e device is fully transparent to serial protocols and applications. It works with any equipment using standard RS232 communication, including PLCs, SCADA systems, and industrial controllers, requiring no software modifications or special drivers.\u003c\/p\u003e\n\n\u003cp class=\"meta-description\"\u003eRS232 Fiber Media Converter with DB-9 Female to 1300nm Multimode SC. Industrial serial to fiber conversion for extended distance communications.\u003c\/p\u003e","brand":"Transition Networks","offers":[{"title":"Default Title","offer_id":39717523062859,"sku":"J\/RS232-CF-01(SC)-NA","price":183.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/products\/RS232-Fiber-Media-Converter-DB-9-Female-to-1300nm-Multimode-SC-Serial-Converter-Tecisoft-JRS232-CF-01SC-NA.jpg?v=1767967875","url":"https:\/\/www.tecisoft.com\/products\/transition-networks-j-rs232-cf-01sc-serial-converter-repeater-isolator-rs-232-fiber-sc","provider":"TeciSoft","version":"1.0","type":"link"}