{"product_id":"tripp-lite-smartpro-120v-3kva-2-25kw-line-interactive-sine-wave-ups-snmp-webcard-pre-installed-2u-rack-tower-lcd-usb-db9-serial","title":"Tripp Lite SmartPro 3000VA Line Interactive UPS - 2U Rack Pure Sine Wave | TeCisoft SMART3000RM2UN","description":"\u003cp\u003e This \u003cstrong\u003esmart ups\u003c\/strong\u003e is perfect for small business owners and IT managers who need reliable \u003cstrong\u003eserver rack battery backup\u003c\/strong\u003e with advanced monitoring capabilities. Our Tripp Lite SmartPro 3000VA delivers:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine interactive topology\u003c\/strong\u003e providing efficient power conditioning and automatic voltage regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure sine wave output\u003c\/strong\u003e ensuring compatibility with sensitive electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork card slot\u003c\/strong\u003e enabling remote monitoring and automated shutdown capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U rack mount design\u003c\/strong\u003e maximizing data center space efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine interactive technology\u003c\/strong\u003e with automatic voltage regulation for optimal power conditioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure sine wave output\u003c\/strong\u003e protecting sensitive servers and networking equipment\u003c\/li\u003e\n\u003cli\u003eOptimized for \u003cstrong\u003enetworkable ups\u003c\/strong\u003e applications with SNMP management card compatibility\u003c\/li\u003e\n\u003cli\u003eConsistent \u003cstrong\u003esmart power protection\u003c\/strong\u003e with LCD display showing real-time status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U rack mountable\u003c\/strong\u003e form factor ideal for space-constrained server rooms\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable style=\"width:100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTripp Lite by Eaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMART3000RM2UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Interactive UPS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000VA \/ 3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V AC ± 25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V AC ± 1% (pure sine wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ± 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-4 milliseconds typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2U Rack Mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSealed lead-acid, maintenance-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Runtime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 minutes at full load, 15 minutes at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 NEMA 5-15R outlets (4 UPS + surge, 4 surge only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB, Serial, Network card slot (SNMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD with input\/output voltage, load, battery status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17\" x 3.4\" x 16.5\" (432 x 86 x 419 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 lbs (23.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 98% in normal mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 1778, FCC Part 15 Class A, CE, Energy Star\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eServers, workstations, networking equipment, storage systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eQ: What are the advantages of line interactive UPS technology?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eLine interactive UPS\u003c\/strong\u003e systems provide automatic voltage regulation and power conditioning while maintaining high efficiency. This \u003cstrong\u003esmart ups\u003c\/strong\u003e corrects voltage fluctuations without switching to battery, extending battery life significantly.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: Why is pure sine wave output important for IT equipment?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003ePure sine wave\u003c\/strong\u003e output ensures compatibility with power factor corrected (PFC) power supplies found in modern servers and networking equipment. This eliminates potential compatibility issues and reduces heat generation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: What network monitoring capabilities are included?\u003c\/strong\u003e\u003cbr\u003eA: This \u003cstrong\u003enetworkable ups\u003c\/strong\u003e includes a network card slot for SNMP management cards, enabling remote monitoring, email notifications, and automated graceful shutdown of connected systems during extended outages.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: How does the 2U rack mount design benefit data centers?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e2U rack mount\u003c\/strong\u003e form factor maximizes space efficiency in server racks while providing \u003cstrong\u003eserver rack battery backup\u003c\/strong\u003e protection for multiple devices in a compact footprint — ideal for small to medium business environments.\u003c\/p\u003e\u003cp class=\"meta-description\"\u003eTripp Lite SmartPro 3000VA line interactive UPS with pure sine wave output. 2U rack mount design with network card slot for smart power protection.\u003c\/p\u003e","brand":"Tripp Lite by Eaton","offers":[{"title":"Default Title","offer_id":39717514936395,"sku":"SMART3000RM2UN","price":2060.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/products\/Tripp-Lite-SmartPro-3000VA-Line-Interactive-UPS-2U-Rack-Pure-Sine-Wave-TeCisoft-SMART3000RM2UN.jpg?v=1767967687","url":"https:\/\/www.tecisoft.com\/products\/tripp-lite-smartpro-120v-3kva-2-25kw-line-interactive-sine-wave-ups-snmp-webcard-pre-installed-2u-rack-tower-lcd-usb-db9-serial","provider":"TeciSoft","version":"1.0","type":"link"}