{"product_id":"vertiv-geist-mj-series-15018vh-metered-rpdu-20a-208v","title":"Vertiv Geist MJ Series 15018VH Metered rPDU 20A 208V","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"who-its-for\"\u003e\u003ch1\u003eVertiv Geist MJ Series Metered rPDU – 20A 208V Rack Power Distribution\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eVertiv Geist MJ Series metered rPDU\u003c\/strong\u003e is engineered for data centers, server rooms, and network closets requiring precise power management and distribution. This \u003cstrong\u003e20A 208V rack-mount PDU\u003c\/strong\u003e provides six rear-facing NEMA L6-20R receptacles, delivering reliable power connectivity with integrated metered monitoring. Ideal for IT professionals managing multi-device rack environments, this unit combines secure twist-lock connectors with real-time current visibility to optimize load distribution and prevent overload conditions.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMetered monitoring for real-time current tracking and load management\u003c\/li\u003e\n\u003cli\u003e20A capacity at 208V for high-density power delivery\u003c\/li\u003e\n\u003cli\u003eSix NEMA L6-20R rear receptacles for secure equipment connections\u003c\/li\u003e\n\u003cli\u003e10-foot input cord with twist-lock L6-20P connector for reliable power inlet\u003c\/li\u003e\n\u003cli\u003eRack-mount design fits standard 19-inch equipment racks\u003c\/li\u003e\n\u003cli\u003eLocal current display for immediate power consumption visibility\u003c\/li\u003e\n\u003cli\u003eCompact form factor maximizes rack space efficiency\u003c\/li\u003e\n\u003cli\u003eSupports redundant power configurations in enterprise environments\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"technical-specs\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"8\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eVertiv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eGeist MJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e15018VH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-20P (twist-lock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord Length\u003c\/td\u003e\n\u003ctd\u003e10 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e6x NEMA L6-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eMetered (local current display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRack-mount (19-inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution Type\u003c\/td\u003e\n\u003ctd\u003eStandard metered rPDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is a metered rPDU and why do I need one?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003emetered rack PDU\u003c\/strong\u003e provides real-time current monitoring at the power distribution point, allowing IT teams to track energy consumption, balance loads across outlets, and prevent circuit overloads. The Vertiv Geist MJ Series delivers this intelligence locally, enabling quick capacity decisions without remote monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eCan this 20A 208V PDU support redundant power supplies?\u003c\/h3\u003e\n\u003cp\u003eYes. The Geist MJ Series is designed for enterprise rack environments where redundant power configurations are standard. Multiple units can be deployed to provide dual power paths for critical equipment, ensuring high availability.\u003c\/p\u003e\n\u003ch3\u003eWhat equipment can connect to the NEMA L6-20R outlets?\u003c\/h3\u003e\n\u003cp\u003eThe six NEMA L6-20R receptacles accommodate any IT equipment with matching L6-20P connectors, including server power supplies, UPS units, and high-power network devices rated for 20A 208V circuits.\u003c\/p\u003e\n\u003ch3\u003eHow does the 10-foot input cord benefit my rack setup?\u003c\/h3\u003e\n\u003cp\u003eThe extended 10-foot cord provides flexibility in positioning the power source away from the rack, reducing cable clutter and allowing cleaner cable management in dense data center environments.\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"VERTIV","offers":[{"title":"Default Title","offer_id":41589624668235,"sku":"15018VH","price":590.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/Vertiv-Geist-MJ-Series-15018VH-Metered-rPDU-20A-208V.png?v=1788293211","url":"https:\/\/www.tecisoft.com\/products\/vertiv-geist-mj-series-15018vh-metered-rpdu-20a-208v","provider":"TeciSoft","version":"1.0","type":"link"}