APC Galaxy VS UPS 10kW 208V with N+1 Power Module
The APC Galaxy VS 10kW UPS is engineered for mission-critical IT environments, data centers, and industrial applications requiring enterprise-grade power protection. This 208V uninterruptible power supply delivers high-efficiency backup power with N+1 redundancy capability, ensuring zero downtime during power events. The modular design supports external batteries for extended runtime, making it ideal for organizations that demand scalable, reliable power infrastructure.
Whether protecting sensitive servers, network equipment, or industrial control systems, the Galaxy VS provides the redundancy and flexibility your critical operations need. The included Start-up 5x8 service ensures professional commissioning and rapid deployment.
Key Features
- 10kW capacity at 208V input/output voltage
- N+1 power module redundancy for continuous operation
- External battery support for extended backup runtime
- High-efficiency double-conversion topology
- Modular architecture for scalability and maintenance
- Advanced monitoring and management capabilities
- Professional Start-up 5x8 commissioning service included
- Designed for data centers and critical infrastructure
Technical Specifications
| Specification |
Details |
| Manufacturer |
APC by Schneider Electric |
| Part Number |
GVSUPS10KRFS |
| Rated Capacity |
10 kW / 10 kVA |
| Input Voltage |
208V AC |
| Output Voltage |
208V AC |
| Power Module Configuration |
N+1 Redundancy |
| External Battery Support |
Yes |
| Service Option |
Start-up 5x8 (Business Hours Commissioning) |
| Topology |
Double-Conversion Online |
| Application |
Data Centers, IT Infrastructure, Industrial Control |
Frequently Asked Questions
What is N+1 power module redundancy in a UPS?
N+1 redundancy means the Galaxy VS includes one additional power module beyond what's required for full capacity. If one module fails, the remaining module continues supplying power without interruption, ensuring your critical systems stay online.
Can I extend the backup runtime on the APC Galaxy VS 10kW?
Yes, the Galaxy VS supports external battery modules, allowing you to customize backup runtime based on your specific requirements. This modular approach provides flexibility for growing power needs.
What does the Start-up 5x8 service include?
Start-up 5x8 provides professional installation, configuration, and commissioning of your UPS system during standard business hours (Monday-Friday, 8AM-5PM). This ensures proper setup and optimal performance from day one.
Is the Galaxy VS suitable for data center environments?
Absolutely. The APC Galaxy VS 10kW is specifically designed for data center and mission-critical IT applications, offering the reliability, redundancy, and scalability required for enterprise infrastructure protection.