Doble F6080 Field Calibration Unit
The Doble F6080 Field Calibration Unit is a portable, high-accuracy calibration solution designed to verify and maintain the performance of Doble F6150 and related protection test instruments. This field calibration unit delivers precise voltage and current measurement, accurate frequency measurement, and logic input timing verification—ensuring your protection test equipment remains properly calibrated for reliable field testing. With RS-232 connectivity, wide operating temperature range, and robust portable design, the F6080 is engineered for demanding field service and high-reliability applications where measurement accuracy is critical.
Key Features
- High-accuracy voltage and current measurement for protection test instrument calibration
- Precise frequency measurement and logic input timing verification
- RS-232 control interface for seamless integration with calibration systems
- Portable field-ready design with robust construction
- Wide operating temperature range for diverse field environments
- 100–240 V, 50/60 Hz universal power supply compatibility
- Dependable performance for high-reliability testing applications
Technical Specifications
| Specification |
Details |
| Manufacturer |
Doble |
| Model/Part Number |
F6080 |
| Product Type |
Field Calibration Unit |
| Primary Application |
Protection Test Instrument Calibration & Verification |
| Compatible Instruments |
Doble F6150 and related protection test instruments |
| Control Interface |
RS-232 |
| Power Supply |
100–240 V, 50/60 Hz |
| Measurement Capabilities |
Voltage, Current, Frequency, Logic Input Timing |
| Form Factor |
Portable |
| Operating Temperature Range |
Wide range for field use |
Frequently Asked Questions
What is the F6080 Field Calibration Unit used for?
The Doble F6080 is used to calibrate and verify the accuracy of Doble F6150 and related protection test instruments in the field. It ensures that your test equipment maintains proper calibration for accurate and reliable testing performance.
How does the F6080 connect to test equipment?
The F6080 Field Calibration Unit connects via RS-232 control interface to a control computer, enabling automated calibration routines and verification procedures for protection test instruments.
Is the F6080 suitable for portable field calibration?
Yes. The F6080 features a portable design with robust construction and wide operating temperature range, making it ideal for field service applications where protection test instrument calibration and verification are required on-site.
What power requirements does the F6080 have?
The F6080 Field Calibration Unit operates from a universal 100–240 V, 50/60 Hz power supply, providing flexibility for use in different geographic locations and field environments.