This ATS rack PDU is perfect for data center administrators and IT professionals who need reliable redundant power management for critical network equipment. Our Eaton TPC2234-3866 automatic transfer switch delivers:
-
Switched power distribution unit functionality with seamless automatic transfer capability
-
1U power distribution unit design for efficient space utilization in server racks
-
Dual C20 input connectors for redundant power source connections
-
8 C13 output outlets for reliable equipment power distribution at 200-240V 16A
Key Features
-
Automatic transfer switch technology for seamless power failover
-
Dual C20 input connectors for redundant power source management
- Optimized for rack mount power distribution applications
- Consistent 200-240V 16A power delivery for enterprise equipment
-
8 IEC C13 output outlets for flexible device connectivity
-
1U horizontal orientation for efficient rack space utilization
Technical Specifications
| Manufacturer |
Eaton |
| Model Number |
TPC2234-3866 |
| Type |
ATS Rack PDU |
| Input Connectors |
(2) C20 Input |
| Output Outlets |
(8) C13 Output |
| Form Factor |
1U Power Distribution Unit |
| Voltage Rating |
200-240V AC |
| Current Rating |
16A |
| Orientation |
1U Horizontal |
| Transfer Type |
Automatic Transfer Switch |
Frequently Asked Questions
Q: What is an ATS rack PDU and how does it work?
A: An ATS rack PDU combines automatic transfer switch technology with power distribution. When the primary power source fails, it automatically switches to the secondary source, ensuring uninterrupted power delivery to connected equipment.
Q: Is this compatible with standard server rack installations?
A: Yes, this 1U power distribution unit is specifically designed for 19-inch server racks. The horizontal orientation maximizes efficiency while the dual C20 inputs provide redundant power connectivity for critical applications.
Q: How many devices can this ATS PDU support?
A: With 8 IEC C13 output outlets and 16A capacity at 200-240V, this unit can support multiple servers, switches, and network equipment — perfect for redundant power applications in data center environments.
Q: Does this unit provide true redundancy?
A: Yes. This switched power distribution unit features dual C20 inputs that can be connected to separate power sources, providing automatic failover capability and ensuring continuous operation of critical infrastructure equipment.
ATS rack PDU for data centers. Eaton automatic transfer switch with dual C20 inputs, 8 C13 outputs, 1U design.