Eaton Ferroresonant 12500VA / 10000W UPS Power Protection System
The Eaton Ferroresonant UPS delivers enterprise-grade power protection with 12500VA capacity and 10000W continuous output. Engineered for mission-critical applications, this ferroresonant topology UPS provides superior voltage regulation and harmonic distortion suppression across 208V, 120V, and 240V configurations. Ideal for data centers, industrial facilities, and sensitive equipment environments requiring reliable backup power and clean energy delivery.
Built on proven ferroresonant transformer technology, this Eaton system ensures stable output voltage even during utility fluctuations, protecting servers, networking equipment, and industrial machinery from power anomalies. The 10000W continuous power rating supports demanding loads while maintaining consistent performance during extended outages.
Key Features
- 12500VA / 10000W power capacity with ferroresonant voltage regulation
- Multiple voltage configurations: 208V, 120V, and 240V input/output support
- Superior harmonic distortion suppression and voltage stabilization
- Ferroresonant transformer topology for enhanced reliability
- Extended runtime capability with optional battery modules
- Hot-swappable battery design for maintenance without downtime
- Audible and visual alarm indicators for system status
- Compact design suitable for rack or floor mounting
- Built-in surge protection and noise filtering
- Manual bypass switch for emergency power routing
Technical Specifications
| Specification |
Details |
| Manufacturer |
Eaton |
| Part Number |
FM200AA0A0A0A0B |
| Topology |
Ferroresonant |
| Power Rating |
12500VA / 10000W |
| Input Voltage |
208V, 120V, 240V (configurable) |
| Output Voltage |
208V, 120V, 240V (stabilized) |
| Frequency |
50/60 Hz |
| Transfer Time |
Instantaneous (ferroresonant design) |
| Battery Type |
Sealed lead-acid (hot-swappable) |
| Mounting Options |
Rack or floor mount |
| Cooling |
Forced-air ventilation |
| Operating Temperature |
0°C to 40°C |
Frequently Asked Questions
What is ferroresonant UPS topology and why is it beneficial?
Ferroresonant topology uses a transformer-based design that provides automatic voltage regulation without active electronics. This approach delivers superior harmonic suppression, exceptional voltage stability, and enhanced reliability for sensitive equipment protection. The Eaton ferroresonant system excels in environments with unstable utility power or high electrical noise.
Can the Eaton 12500VA UPS support different voltage configurations?
Yes, this 12500VA power protection system supports multiple voltage configurations including 208V, 120V, and 240V input and output options. This flexibility allows deployment across diverse facility requirements and international applications.
How long will the UPS provide backup power during an outage?
Runtime depends on the battery module configuration and connected load. The standard configuration provides several minutes of runtime at full load. Extended runtime is available through optional additional battery modules, allowing you to customize backup duration for your specific requirements.
Is the Eaton ferroresonant UPS suitable for data center applications?
Absolutely. The Eaton 10000W UPS is specifically designed for mission-critical environments including data centers, server rooms, and industrial facilities. Its ferroresonant design ensures clean, stable power delivery that protects expensive IT equipment and prevents data loss during power events.