Raritan PX3-1085I2U-V2 Rack PDU
The Raritan PX3-1085I2U-V2 is a metered rack PDU engineered for high-density data centers and IT environments requiring precise power distribution and real-time energy monitoring. This 3-phase power distribution unit delivers 17.3kVA capacity across 48 outlets, making it ideal for organizations managing complex power infrastructure across multiple server racks. With advanced metering accuracy of ±1% and cascading capabilities for up to 16 units, this rack PDU solution provides the visibility and control needed to optimize power consumption, reduce downtime, and maintain compliance in mission-critical environments.
Key Features
- 48 outlets for flexible power distribution across high-density server environments
- 17.3kVA power capacity with 415V 3-phase Wye input configuration
-
Metered power monitoring with ±1% accuracy for current, voltage, power, and energy
- Onboard embedded processor for intelligent power management and real-time analytics
- Cascading support for up to 16 PDUs via single Ethernet or USB connection
- Vertical 0U form factor for space-efficient rack mounting
- Advanced energy monitoring for detailed consumption tracking and reporting
- Remote management capabilities for centralized control and visibility
Technical Specifications
| Specification |
Details |
| Manufacturer |
Raritan |
| Model Number |
PX3-1085I2U-V2 |
| Product Series |
PX3 Series |
| Type |
Metered Rack PDU |
| Form Factor |
Vertical 0U |
| Outlet Count |
48 outlets |
| Power Capacity |
17.3kVA |
| Input Voltage |
415V 3-Phase Wye |
| Metering Accuracy |
±1% (current, voltage, power, energy) |
| Cascading Capability |
Up to 16 PDUs via Ethernet or USB |
| Processor |
Onboard embedded processor |
| Monitoring |
Real-time energy monitoring and analytics |
Frequently Asked Questions
What is a metered rack PDU and why do I need one?
A metered rack PDU provides real-time visibility into power consumption across your server infrastructure. The Raritan PX3-1085I2U-V2 delivers precise energy monitoring with ±1% accuracy, enabling data center managers to identify power inefficiencies, optimize cooling, reduce energy costs, and prevent overload conditions before they impact operations.
How many PDUs can I cascade with the PX3-1085I2U-V2?
The PX3-1085I2U-V2 supports cascading of up to 16 PDUs through a single Ethernet or USB connection. This cascading capability simplifies management of large-scale power distribution infrastructure, allowing centralized monitoring and control across multiple units without requiring individual connections for each device.
What are the power specifications for this 3-phase PDU?
This 3-phase power distribution unit is rated for 415V 3-phase Wye input with a maximum capacity of 17.3kVA. The 48-outlet configuration provides flexible power distribution for high-density server environments, supporting demanding workloads while maintaining precise metering and monitoring across all connected equipment.
Is the PX3-1085I2U-V2 suitable for high-density data centers?
Yes, the Raritan PX3-1085I2U-V2 is specifically designed for high-density IT environments. Its vertical 0U form factor maximizes rack space efficiency, the 48-outlet configuration supports dense server deployments, and advanced energy monitoring helps optimize power utilization in space-constrained data center facilities.