Raritan PX3-5299 480V 3-Phase Rack PDU
The Raritan PX3-5299-F5N3Q3V2 is a high-capacity rack PDU engineered for enterprise data centers and mission-critical facilities requiring robust power distribution. This 480V, 3-phase Wye configuration delivers 66.5kVA capacity with 80A rating, making it ideal for large-scale server environments, virtualization clusters, and high-density computing deployments. Built for organizations that demand precise energy monitoring, redundancy, and real-time power visibility across distributed infrastructure.
Key Features
- 480V 3-Phase Wye input configuration for balanced power distribution
- 66.5kVA capacity with 80A rating for high-density rack environments
- Advanced energy metering: voltage, current, active power, real power, and power factor monitoring
- Real-time energy consumption tracking and analytics
- Comprehensive power factor analysis for efficiency optimization
- Enterprise-grade reliability and fault tolerance
- Scalable monitoring across multiple PDU units
- Integrated outlet-level power management and control
Technical Specifications
| Specification |
Value |
| Manufacturer |
Raritan |
| Model |
PX3-5299-F5N3Q3V2K002 |
| Input Voltage |
480V, 3-Phase Wye |
| Capacity |
66.5kVA |
| Current Rating |
80A |
| Metering Capabilities |
Voltage, Current, Active Power, Real Power, Energy, Power Factor |
| Form Factor |
Rack-mounted PDU |
| Application |
Data Center, Enterprise Infrastructure |
Frequently Asked Questions
What is a 480V 3-phase rack PDU used for?
A 480V 3-phase rack PDU distributes high-voltage power across multiple servers and network equipment in data centers. The 3-phase Wye configuration ensures balanced load distribution, reducing power loss and improving efficiency in large-scale deployments.
How does energy metering improve data center operations?
Real-time energy metering on the Raritan PX3-5299 enables IT teams to monitor voltage, current, active power, and power factor across all connected devices. This visibility reduces energy waste, identifies overloaded circuits, and optimizes cooling requirements.
What is power factor and why does it matter?
Power factor measures the efficiency of power usage. The PX3-5299's power factor monitoring helps data centers identify reactive power issues, reduce utility penalties, and improve overall electrical system efficiency.
Is the Raritan PX3-5299 suitable for high-density server environments?
Yes. With 66.5kVA capacity and 80A rating, this rack PDU is designed for high-density computing environments where multiple servers and network devices require simultaneous, reliable power distribution with advanced monitoring.