Raritan PX3-5785V-V2 3-Phase PDU 208V 60A with 48 C13 & 6 C19 Outlets
The Raritan PX3-5785V-V2 is a high-capacity rack PDU engineered for mission-critical data center environments requiring robust 3-phase delta 208V power distribution. This 60A PDU delivers 54 total outlets (48 C13 and 6 C19) in a single rack unit, making it ideal for dense server deployments, blade enclosures, and enterprise infrastructure. With embedded processor intelligence and cascading support for up to 16 PDUs via single Ethernet or USB connection, this 3-phase rack PDU provides centralized power monitoring and management at scale.
Key Features
- 54 Total Outlets: 48 C13 + 6 C19 for maximum outlet density
- 3-Phase Delta 208V Input with 60A capacity for high-power applications
- Embedded Processor for real-time power monitoring and analytics
- Cascading Support: Manage up to 16 PDUs with single Ethernet or USB connection
- Rack-Optimized Design: Single RU form factor for space-efficient deployment
- Enterprise-Grade Reliability: Built for 24/7 data center operations
Technical Specifications
| Specification |
Details |
| Manufacturer |
Raritan |
| Model Number |
PX3-5785V-V2 |
| Input Voltage |
3-Phase Delta 208V |
| Input Current |
60A |
| C13 Outlets |
48 |
| C19 Outlets |
6 |
| Total Outlets |
54 |
| Form Factor |
1U Rack Mount |
| Processor |
Embedded Processor with Monitoring |
| Connectivity |
Ethernet, USB |
| Cascading Capacity |
Up to 16 PDUs per connection |
Frequently Asked Questions
What is a 3-phase PDU and why do I need one?
A 3-phase PDU like the Raritan PX3-5785V-V2 distributes power across three electrical phases, providing higher capacity and efficiency than single-phase units. This 208V 3-phase rack PDU is essential for large data centers and enterprise environments where power density and redundancy are critical.
How many servers can this 60A PDU support?
With 54 total outlets (48 C13 and 6 C19), this Raritan 60A PDU can support dozens of servers depending on individual power consumption. The 6 C19 outlets accommodate high-power devices like blade servers, while 48 C13 outlets serve standard rack equipment.
Can I manage multiple PDUs with this unit?
Yes. The embedded processor enables cascading support for up to 16 PDUs using a single Ethernet or USB connection, allowing centralized monitoring and control of your entire power infrastructure from one management interface.
What are the differences between C13 and C19 outlets?
C13 outlets are standard for most servers and networking equipment, while C19 outlets support higher-power devices like blade servers and storage arrays. This PDU with 48 C13 and 6 C19 outlets provides flexibility for mixed-load environments.