Vertiv SmartRow 2 In-Row Cooling Solution for 3-Rack Environments
The Vertiv SmartRow 2 is a purpose-built in-row cooling system designed for organizations managing compact IT infrastructure with demanding thermal requirements. This integrated solution delivers 10 kW cooling capacity at 208V single-phase power, supporting up to 3 racks with redundant cooling units and intelligent hot air management. Perfect for edge data centers, server rooms, and colocation facilities requiring space-efficient thermal control without sacrificing reliability or performance.
With N+1 redundancy built into its dual cooling units, SmartRow 2 ensures continuous operation even during maintenance or component failure. The cold air containment system maximizes cooling efficiency by directing chilled air precisely where needed, while hot air management prevents thermal recirculation. This configuration eliminates hot spots, reduces energy waste, and extends equipment lifespan in space-constrained environments.
Key Features
-
In-row cooling design — Integrated directly into rack infrastructure for maximum efficiency
-
N+1 redundancy — Dual cooling units ensure continuous operation with automatic failover
-
Cold air containment — Precision airflow management prevents thermal mixing and hot spots
-
Hot air management — Intelligent exhaust handling optimizes cooling performance
- 10 kW cooling capacity at 208V single-phase power
- Supports up to 3 racks in single deployment
- Compact form factor for space-constrained data centers
- Vertiv reliability and enterprise-grade thermal management
Technical Specifications
| Specification |
Details |
| Manufacturer |
Vertiv |
| Product Line |
SmartRow 2 |
| Part Number |
SR2N03010FAA1-SVC |
| Cooling Capacity |
10 kW |
| Power Supply |
208V, Single-Phase (2N) |
| Rack Support |
3 Racks |
| Cooling Units |
2 In-Row Units (N+1 Redundancy) |
| Containment Type |
Cold Air Containment with Hot Air Management |
| Redundancy Model |
N+1 (Fault-Tolerant) |
Frequently Asked Questions
What is in-row cooling and why does my data center need it?
In-row cooling places thermal management units directly within server racks, delivering chilled air at the source of heat generation. This approach eliminates long-distance airflow paths, reduces energy consumption by 20-40% compared to traditional room-based cooling, and prevents hot spots that damage equipment. For facilities with high-density server deployments or limited floor space, in-row cooling is essential for maintaining optimal operating temperatures.
How does N+1 redundancy protect my infrastructure?
N+1 redundancy means you have one more cooling unit than required for normal operation. If one unit fails or requires maintenance, the second unit automatically compensates, ensuring uninterrupted cooling. With SmartRow 2's dual cooling units, you maintain full 10 kW capacity even during component failure, eliminating downtime risk and enabling planned maintenance without service interruption.
Does cold air containment really improve cooling efficiency?
Yes. Cold air containment prevents cooled air from mixing with hot exhaust, which wastes energy and creates thermal dead zones. By directing chilled air precisely to intake vents and containing hot air separately, SmartRow 2 achieves 15-25% better cooling efficiency, reduces hot spots by up to 30°C, and lowers overall power consumption for equivalent cooling output.
Is the Vertiv SmartRow 2 suitable for edge data centers?
Absolutely. The compact 3-rack configuration, 10 kW capacity, and 208V single-phase power make SmartRow 2 ideal for edge deployments, remote server rooms, and colocation facilities where space and power are limited. Its integrated design requires minimal installation complexity while delivering enterprise-grade thermal management and redundancy.